We are pleased to offer procurement for Sensata Technologies Inc part number APL111-1-42F-303 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-513-3077 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number APL111-1-42F-303 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-513-3077. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number APL111-1-42F-303 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-513-3077 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015133077 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
APL111-1-42F-303 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AKPX | Pole Quantity | 3 |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
BBRJ | Special Handling Feature | MAGNETIC |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CBBL | Features Provided | HIGH INRUSH PROTECTION |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.156S INCHES MINIMUM AND 2.344 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
THSD | Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.138 INCHES |
AAQL | Body Style | |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.553 INCHES MAXIMUM |
ADAQ | Body Length | 2.510 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
AGAV | End Item Identification | MULTIPLE APPLICATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 30.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
ZZZK | Specification/Standard Data | 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
TEST | Test Data Document | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |