We are pleased to offer procurement for Sensata Technologies Inc part number IULHK1119-30372-20 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-501-6074 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number IULHK1119-30372-20 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-501-6074. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number IULHK1119-30372-20 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-501-6074 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015016074 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
IULHK1119-30372-20 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.250 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC THIRD LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 120.0 MILLIAMPERES DC FOURTH LOCATION |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 70.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AJEC | Boss Height | 1.042 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED STUD |
ADAT | Body Width | 2.490 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
AGAV | End Item Identification | 5895-01-467-7213 |
ADTV | Case Material | METAL |
AJWX | Mounting Surface To Terminal End Distance | 2.529 INCHES NOMINAL |
ADAQ | Body Length | 3.015 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT FIRST LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT THIRD LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.000 NOMINAL AT 125 PCT FOURTH LOCATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.