We are pleased to offer procurement for Sensata Technologies Inc part number AP12-1-71-752 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-487-6017 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number AP12-1-71-752 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-487-6017. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number AP12-1-71-752 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-487-6017 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014876017 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP12-1-71-752 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 7.5 AMPERES AC SINGLE LOCATION |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AKPX | Pole Quantity | 2 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 4 WIRE HOOK |
THSD | Thread Series Designator | UNEF |
ADTV | Case Material | METAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
AAQL | Body Style | |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote