We are pleased to offer procurement for Sensata Technologies Inc part number UPL-11-1-52-503 here on NSN Portal, a Circuitbreaker product that is listed with the NSN 5925-01-457-5156 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number UPL-11-1-52-503 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-457-5156. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number UPL-11-1-52-503 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-457-5156 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014575156 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
IELHK11-1-52-50.0-01-V | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.060 INCHES NOMINAL |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
AKPX | Pole Quantity | 2 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADAT | Body Width | 1.940 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 THREADED STUD |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
THSD | Thread Series Designator | UNC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.000 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 2.490 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.438 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES DC ALL LOCATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.700 MINIMUM AT 200 PCT ALL LOCATIONS AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.