We are pleased to offer procurement for Sensata Technologies Inc part number UPGH6616275221 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-455-4102 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number UPGH6616275221 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-455-4102. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number UPGH6616275221 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-455-4102 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014554102 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
UPGH6616275221 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 7.5 AMPERES AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRP | Ultimate Trip Time Per Pole In Seconds | 10.000 MINIMUM ALL LOCATIONS AND 120.000 MAXIMUM ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
FEAT | Special Features | HANDLE IS RED WITH WHITE MARKINGS |
ADAU | Body Height | 1.640 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
THSD | Thread Series Designator | UNC |
MRC | Decoded Requirement | Clear Text Reply |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote