We are pleased to offer procurement for Sensata Technologies Inc part number AP17-1-51-502 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-407-3081 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number AP17-1-51-502 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-407-3081. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number AP17-1-51-502 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-407-3081 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014073081 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP17-1-51-502 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.375 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 500.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADAT | Body Width | 1.250 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CQJX | Nominal Thread Size | 0.375 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
ADAQ | Body Length | 1.500 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
THSD | Thread Series Designator | UNEF |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.090 MINIMUM AT 200 PCT ALL LOCATIONS AND 60.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |