We are pleased to offer procurement for Sensata Technologies Inc part number AP16-2R-7331-1 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-158-4168 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number AP16-2R-7331-1 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Sensata Technologies Inc through the CAGE Code 81541, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-158-4168. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number AP16-2R-7331-1 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-158-4168 Item Description: CIRCUIT BREAKER | 5925 | 011584168 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP16-2R-7331-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | POLE QUANTITY | 2 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 0.6 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 4.000 MINIMUM SECOND LOCATION AND 40.000 MAXIMUM SECOND LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 6.000 MINIMUM FIRST LOCATION AND 50.000 MAXIMUM FIRST LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 125 PCT SECOND LOCATION AND 40.000 MAXIMUM AT 125 PCT SECOND LOCATION AND 0.850 MINIMUM AT 200 PCT SECOND LOCATION AND 4.000 MAXIMUM AT 200 PCT SECOND LOCATION AND 0.001 MINIMUM AT 400 PCT SECOND LOCATION AND 0.500 MAXIMUM |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 125 PCT FIRST LOCATION AND 50.000 MAXIMUM AT 125 PCT FIRST LOCATION AND 0.900 MINIMUM AT 200 PCT FIRST LOCATION AND 4.000 MAXIMUM AT 200 PCT FIRST LOCATION AND 0.010 MINIMUM AT 400 PCT FIRST LOCATION AND 0.090 MAXIMUM AT 40 |
FREQ | FREQUENCY IN HERTZ | 400.0 FIRST LOCATION |