We are pleased to offer procurement for Schneider Electric Gmbh part number 9012ADR26 here on NSN Portal, a Switch Pressure product that is listed with the NSN 5930-01-188-4215 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 9012ADR26 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Schneider Electric Gmbh through the CAGE Code 51918, as well as falls under FSC 5930 Switches based on having the NSN 5930-01-188-4215. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 9012ADR26 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-188-4215 Item PartTypeName: SWITCH,PRESSURE | 5930 | 011884215 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9012ADR26 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARX | INSIDE DIAMETER | 0.250 INCHES NOMINAL FIRST CONNECTION0.750 INCHES NOMINAL SECOND CONNECTION |
ABHP | OVERALL LENGTH | 8.180 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.380 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 7.060 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.440 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.880 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AWTN | OPERATING TEMP RATING | -10.0 DEG FAHRENHEIT MINIMUM AND 185.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJB | PROOF PRESSURE | 15000.00 POUNDS PER SQUARE INCH GAGE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES FIRST PRESSURE CONNECTION0.750 INCHES SECOND PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 6.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 3.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE1.5 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 1.5 AMPERES INDUCTIVE L |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 90.00/2900.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE240.0 AC AT SEA LEVEL SECOND VOLTAGE480.0 AC AT SEA LEVEL THIRD VOLTAGE600.0 AC AT SEA LEVEL FOURTH VOLTAGE125.0 DC AT SEA LEVEL FIFTH VOLTAGE250.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN,THREADED INTERNAL ALL CONNECTIONS |
FREQ | FREQUENCY IN HERTZ | 50.0 FIRST VOLTAGE AND 60.0 FIRST VOLTAGE50.0 SECOND VOLTAGE AND 60.0 SECOND VOLTAGE50.0 THIRD VOLTAGE AND 60.0 THIRD VOLTAGE50.0 FOURTH VOLTAGE AND 60.0 FOURTH VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
THSD | THREAD SERIES DESIGNATOR | NPT ALL PRESSURE CONNECTION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote