We are pleased to offer procurement for L 3 Communications Westwood part number 302-12-104 here on NSN Portal, a Circuitbreaker product that is listed with the NSN 5925-01-359-1969 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 302-12-104 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to L 3 Communications Westwood through the CAGE Code 58475, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-359-1969. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 302-12-104 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-359-1969 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013591969 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
302-12-104 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC AND 250.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 100000.0 AC AND 100000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
FEAT | SPECIAL FEATURES | 115.0 VAC,60 HZ SHUNT TRIP DEVICE INCLUDED |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
ABMK | OVERALL WIDTH | 3.125 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 75.0 AMPERES AC AND 75.0 AMPERES DC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
AKPX | POLE QUANTITY | 3 |
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.375 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote