We are pleased to offer procurement for Harris Corporation part number 6049-5100 here on NSN Portal, a Transformer Power product that is listed with the NSN 5950-00-481-8132 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 6049-5100 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Harris Corporation through the CAGE Code 14304, as well as falls under FSC 5950 Coils and Transformers based on having the NSN 5950-00-481-8132. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 6049-5100 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-481-8132 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004818132 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1019 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 24.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 12.120 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 17.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE AND SLOT ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 17.940 INCHES MINIMUM AND 18.060 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.630 INCHES MINIMUM AND 6.870 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABTB | MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL 1ST GROUP |
ACZB | FREQUENCY RATING | 47.5 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |