We are pleased to offer procurement for General Electric Company part number CR1062R7A here on NSN Portal, a Starter Motor product that is listed with the NSN 6110-00-631-2983 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number CR1062R7A or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to General Electric Company through the CAGE Code 28339, as well as falls under FSC 6110 Electrical Control Equipment based on having the NSN 6110-00-631-2983. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number CR1062R7A today and take advantage of our industry-leading services.
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |
ABHP | OVERALL LENGTH | 5.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 9.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.625 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 220.0 VOLTS MINIMUM AND 600.0 VOLTS MAXIMUM |
ACZB | FREQUENCY RATING | 25.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
AFLW | ACTUATION METHOD | MANUAL |
AGLD | PERFORMANCE TYPE | MANUAL |
ALGC | MOUNTING CONFIGURATION | FOUR 1/4 IN. DIA KNOCKOUTS ON 8-1/4 IN. BY 3 IN. MTG CENTERS |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ANCY | HORSEPOWER RATING | 2.000 AND 3.000 |
ANDW | LOAD PROTECTION TYPE | OVERLOAD |
ANPZ | INCLOSURE FEATURE | PROTECTED |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | NOT DESIGNED PER NEMA STD |
AQZF | CONTROL TYPE | LOCAL |
FAAZ | PHASE | TWO OR THREE |