We are pleased to offer procurement for General Electric Company part number 9T11Y5502 here on NSN Portal, a Transformer Power product that is listed with the NSN 5950-00-620-0111 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 9T11Y5502 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to General Electric Company through the CAGE Code 24446, as well as falls under FSC 5950 Coils and Transformers based on having the NSN 5950-00-620-0111. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 9T11Y5502 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-620-0111 Item Description: TRANSFORMER,POWER | 5950 | 006200111 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9T11Y5502 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CWJS | Winding Operating Voltage | 450.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
MRC | Decoded Requirement | Clear Text Reply |
FEAT | Special Features | 3.6 PERCENT IMPEDANCE |
ACZB | Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
BPLC | Winding Function And Quantity | 1 PRIMARY AND |
BPLC | Winding Function And Quantity | 1 SECONDARY SINGLE COMPONENT |
ABTB | Mounting Hole Diameter | 0.438 INCHES NOMINAL SINGLE GROUP |
ACZF | Maximum Transformer Power Rating | 5.0 KILOVOLT-AMPERE SINGLE COMPONENT |
BFMF | Cooling Method | SELF-COOLED |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT | Body Width | 7.590 INCHES NOMINAL |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 6.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | Inclosure Type | FULLY INCLOSED |
ADAQ | Body Length | 11.840 INCHES NOMINAL |
ADAU | Body Height | 5.880 INCHES NOMINAL |
AXGY | Mounting Method | FLANGE AND |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |