We are pleased to offer procurement for Gems Sensors Inc part number LS16500-12 here on NSN Portal, a Switch Liquid Level product that is listed with the NSN 5930-00-407-5260 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number LS16500-12 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Gems Sensors Inc through the CAGE Code 04034, as well as falls under FSC 5930 Switches based on having the NSN 5930-00-407-5260. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number LS16500-12 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-407-5260 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 004075260 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LS16500-12 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 13.187 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 110.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | 220.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ADAV | OVERALL DIAMETER | 5.562 INCHES NOMINAL |
AEEE | CONNECTOR MANUFACTURER CODE | 77820 |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | CONNECTOR RECEPTACLE |
AGBG | CONNECTOR IDENTIFICATION | BENDIX 10-214216-4P |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 2ND ALTERNATE OPERATING POWER RQMT |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES NOMINAL LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 110.0 VOLTS |
AWAE | FLOAT QUANTITY | 1 |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | FLANGE |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 10.0 AMPERES NOMINAL LOAD |
BJKD | CONTACT ARRANGEMENT | ST.S.P. N.O.DRY |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | HYDRAULIC OIL AND LUBRICANT AND SEA WATER AND VARIOUS FUELS AND WATER |
BJKN | FLOAT EFFECTIVE TRAVEL | 8.500 INCHES NOMINAL |
BJKP | MOUNTING DIMENSIONS | 6-0.562IN.DIA.HOLES ON 4.437IN.B.CENTERS |
BJKQ | TANK INSERTION LENGTH | 10.750 INCHES NOMINAL |
FAAZ | PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
FAAZ | PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |