We are pleased to offer procurement for Emerson Electric Gmbh And Co part number 300-049197-001 here on NSN Portal, a Switch Thermostatic product that is listed with the NSN 5930-00-602-1599 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 300-049197-001 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Emerson Electric Gmbh And Co through the CAGE Code 97409, as well as falls under FSC 5930 Switches based on having the NSN 5930-00-602-1599. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 300-049197-001 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-602-1599 Item Description: SWITCH,THERMOSTATIC | 5930 | 006021599 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
300-049197-001 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQGB | Contact Action Stimulus | DECREASE |
ABHP | Overall Length | 2.1875 INCHES NOMINAL |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE |
AXGY | Mounting Method | THREADED HOLE AND |
AEVT | Capillary Tube Length | 15.0 INCHES NOMINAL |
AAJD | Thread Class | 2B SINGLE PRESSURE CONNECTION |
CTYM | Contact Adjustment Range | 55.00 TO 105.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | Contact Adjustment Type | EXTERNAL ACTUATION POINT DIAL |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE |
ABMK | Overall Width | 1.250 INCHES NOMINAL |
CTYX | Contact Stimulus Rating | 3.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | Contact Voltage Rating In Volts | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
STYL | Style Designator | RECTANGULAR |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
AXGY | Mounting Method | UNTHREADED HOLE |
CTYC | Contact Adjustability | DEACTUATION POINT NOT ADJUSTABLE AND |
CTZB | Contact Voltage Rating In Volts | 277.0 AC AT SEA LEVEL FIRST VOLTAGE |
AEJN | Distance Between Mounting Facility Centers | 1.750 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES SINGLE PRESSURE CONNECTION |
ADAQ | Body Length | 1.4375 INCHES NOMINAL |
AEVU | Bulb Length | 5.500 INCHES NOMINAL |
ABKW | Overall Height | 2.6875 INCHES NOMINAL |
THSD | Thread Series Designator | UNC SINGLE PRESSURE CONNECTION |
AKBY | Temp Sensing Element Type | CAPILLARY TUBE-BULB |
CTHF | Contact Load Current Rating | 22.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | Contact Load Current Rating | 25.0 AMPERES RESISTIVE LOAD AND |
CTHF | Contact Load Current Rating | 10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CMLP | Thread Quantity Per Inch | 32 SINGLE PRESSURE CONNECTION |
AEJN | Distance Between Mounting Facility Centers | 1.3125 INCHES MINIMUM AND |
CSCF | Terminal Type | WIRE LEAD |
MEDA | Media For Which Designed | GAS |
AEVV | Bulb Diameter | 0.375 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.4375 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote