We are pleased to offer procurement for Eaton Corporation part number PWHR12120W3FR here on NSN Portal, a Battery Storage product that is listed with the NSN 6140-01-647-1535 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number PWHR12120W3FR or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Eaton Corporation through the CAGE Code 5H7N6, as well as falls under FSC 6140 Batteries Rechargeable based on having the NSN 6140-01-647-1535. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number PWHR12120W3FR today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6140-01-647-1535 Item PartTypeName: BATTERY,STORAGE | 6140 | 016471535 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PWHR12120W3FR | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ELEC | Voltage In Volts | 12 |
AGEB | Fording Feature | NOT INCLUDED |
AFKS | Commercial Battery Size Designation | 12 VOLT |
APXH | Terminal Location | TOP |
AQHD | Nonspilling Feature | NOT INCLUDED |
AQHE | Discharge Rate In Amps | 12 |
ABFY | Overall Depth | 4.86 INCHES MINIMUM AND 4.98 INCHES MAXIMUM |
AQGQ | Cell Quantity | 6 |
AQHF | Charge Indicator | NOT INCLUDED |
AQHJ | Integral Charging Facility | NOT INCLUDED |
ABMK | Overall Width | 6.45 INCHES MINIMUM AND 6.61 INCHES MAXIMUM |
CXCY | Part Name Assigned By Controlling Agency | BATTERY UNIT |
MRC | Decoded Requirement | Clear Text Reply |
AARA | Terminal Quantity | 2 |
ARGW | Plate Type | NEGATIVE AND POSITIVE |
CWFH | Case Design Type | SEALED |
AEXT | Battery Electrolyte | LEAD ACID |
ABKW | Overall Height | 6.81 INCHES MINIMUM AND 6.89 INCHES MAXIMUM |
AQGP | Approximate Shelf Life | 10.0 YEARS |
AQHG | Electrolyte Level Indicator | NOT INCLUDED |
FEAT | Special Features | CAPACITY: 120W @ 15-MINUTE RATE TO 1.67V PER CELL @ 77?F (25?C); WEIGHT: 23.6 LB; MAXIMUM DISCHARGE CURRENT: 400A (5 SEC); INTERNAL RESISTANCE: 8 MILLIOHM; OPERATING TEMPERATURE RANGE: DISCHARGE: 5?F~122?F (-15?C~50?C); CHARGE: 5?F~104?F (-15?C~40?C); STORAGE: 5?F~104?F (-15?C~40?C); TERMINAL: 12-THREAD LEAD ALLOY RECESSED TERMINAL TO ACCEPT M6 BOLT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote