We are pleased to offer procurement for Eaton Corporation part number AM3-A8-A-10-0-20 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-01-228-9058 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number AM3-A8-A-10-0-20 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Eaton Corporation through the CAGE Code 74193, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-01-228-9058. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number AM3-A8-A-10-0-20 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-228-9058 Item Description: CIRCUIT BREAKER | 5925 | 012289058 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM3-A8-A-10.0-20 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
THSD | Thread Series Designator | UNC |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 12.000 OUNCES |
AKPX | Pole Quantity | 3 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CBBL | Features Provided | HIGH INRUSH PROTECTION |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.240 INCHES MINIMUM AND 2.251 INCHES MAXIMUM |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT AND 11.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CMLP | Thread Quantity Per Inch | 32 |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote