We are pleased to offer procurement for Eaton Corporation part number AM333HEMG6-15-250-400-14 here on NSN Portal, a Circuit Breaker product that is listed with the NSN 5925-00-403-4061 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number AM333HEMG6-15-250-400-14 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Eaton Corporation through the CAGE Code 74193, as well as falls under FSC 5925 Circuit Breakers based on having the NSN 5925-00-403-4061. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number AM333HEMG6-15-250-400-14 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-403-4061 Item Description: CIRCUIT BREAKER | 5925 | 004034061 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM333HEMG6-15-250-400-14 | 3 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | SALT SPRAY PROOF |
MRC | Decoded Requirement | Clear Text Reply |
BBRJ | Special Handling Feature | MAGNETIC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
THSD | Thread Series Designator | UNC |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
TEST | Test Data Document | 13499-260-4015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AKPX | Pole Quantity | 3 |
CSSX | Switch Current Rating And Type In Amps | 1.0 DC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.250 INCHES NOMINAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AAJE | Thread Pitch Diameters | 0.1177 TO 0.1214 INCHES |
CSWP | Switch Voltage Rating And Type In Volts | 50.0 DC |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.611 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
PKWT | Unpackaged Unit Weight | 14.250 OUNCES |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote