We are pleased to offer procurement for Drs Power And Control Technologies part number 11003H44B30 here on NSN Portal, a Resistor Fixed Wire Wound Induct product that is listed with the NSN 5905-01-093-9414 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 11003H44B30 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Drs Power And Control Technologies through the CAGE Code 27192, as well as falls under FSC 5905 Resistors based on having the NSN 5905-01-093-9414. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 11003H44B30 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-093-9414 Item PartTypeName: RESISTOR,FIXED,WIRE WOUND,INDUCT | 5905 | 010939414 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
11003H44B30 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -260.0 TO 260.0-260.0 TO 260.0-260.0 TO 260.0-260.0 TO 260.0-260.0 TO 260.0 |
AAPP | ELECTRICAL RESISTANCE | 30.000 OHMS30.000 OHMS30.000 OHMS30.000 OHMS30.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000 |
AAPR | FIXED TAP QUANTITY | 11111 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0350.0350.0350.0350.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 350.0-55.0 TO 350.0-55.0 TO 350.0-55.0 TO 350.0-55.0 TO 350.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.844 INCHES NOMINAL0.844 INCHES NOMINAL0.844 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.937 INCHES NOMINAL0.937 INCHES NOMINAL0.937 INCHES NOMINAL |
ADAQ | BODY LENGTH | 5.000 INCHES NOMINAL5.000 INCHES NOMINAL5.000 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 75.000 FREE AIR75.000 FREE AIR75.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS25.0 DEG CELSIUS25.0 DEG CELSIUS |
AFWW | TERMINAL WIDTH | 0.250 INCHES NOMINAL0.250 INCHES NOMINAL0.250 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | ENCAPSULATEDENCAPSULATEDENCAPSULATED |
CQFD | SECTION NOMINAL RESISTANCE | 15.000 OHMS 1ST SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 15.000 OHMS 2ND SECTIONUNABLE TO DECODE |
CQFK | FIXED TAP TERMINAL TYPE | TAB W/SCREWTAB W/SCREW |
CSCF | TERMINAL TYPE | TAB W/SCREWTAB W/SCREW |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH END |