We are pleased to offer procurement for Clark Equipment Company part number 44014967 here on NSN Portal, a Relay Electromagnetic product that is listed with the NSN 5945-01-194-4241 for ease of identification. You have reached our Request for Quote (RFQ) form for this listing, where you are encouraged to submit details on your requirements to receive tailored purchasing options from our staff. As you will see, we ask that you offer key information on your pricing target, desired quantity, and more, as this will ensure that the representative who responds to your request is able to provide the most fitting solutions for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
Whether you procure part number 44014967 or other NSN products from our website, you can rest assured that we uphold full traceability for all items. For example, this particular listing traces back to Clark Equipment Company through the CAGE Code 33968, as well as falls under FSC 5945 Relays and Solenoids based on having the NSN 5945-01-194-4241. Furthermore, every purchase will be delivered with any applicable qualifying certifications or manufacturer trace documentation as per our NO CHINA SOURCING pledge. If you are ready to experience why professionals rely on us for their needs, request a quote for part number 44014967 today and take advantage of our industry-leading services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-194-4241 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 011944241 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
44014967 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 12.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TAB,SOLDER LUG ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 2.250 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.875 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.964 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 44.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |